Industrial Wastewater Treatment Success Stories

Diesel Steam Power Plant Oily Wastewater Emulsion

Bahamas Power Plant Improves Efficiencies

Diesel/Steam Power Plant Oily/Water Emulsion - The waste water is from the operations of a steam power plant located in the Bahamas. The wastewater samples were taken from the Unit 31 (lower oil content) and Tank #3 (a higher oil content). Some of the lab test parameters were:

  Unit 31 Tank #3
pH 7.18 7.16
Conductivity 1,034 uS 1,547 uS
Total Dissolved Solids 543 ppm 820 ppm
Suspended Solids, untreated 142 ppm 758 ppm
Suspended Solids, treated 4 ppm 18 ppm
Chemical Oxygen Demand, untreated 120 ppm 1,100
Chemical Oxygen Demand, treated 16 ppm 820
Oil & Grease, untreated 121 ppm 209 ppm
Oil and Grease, treated 3.1 ppm 7.6 ppm

The samples were tested and it was found through the jar testing procedures that the Floccin K was the best choice for floc size and water clarity. The Unit 31 was dosed at 0.5 gram in 1,000 ml and the Tank # 3 water was dosed at 1.0 gram in 1,000 ml. The results are shown below:

Read the full study...

 

To download this and more case studies click here>>>

Obtain Your Free Evaluation...Get Started

Integrated Engineers Inc Logo

Learn How to $$Save$$


Copyright 1994 - 2008 Integrated Engineers Inc