Manufacturing Wastewater Treatment Case Studies
Metal Processing Facility 2 Treatment of Wastewater Test
Current Chemistry
Integrated Engineers, Inc. conducted the below treatability on a Metal Processing facility that uses soluble metal cutting oils in their machining process; below are the results.
Untreated Parameters:
- pH = 7.0
- Conductivity = 4,560 microSiemens (uS)
The treatment required no pH adjustment from the 7.0 pH. The best product was treated with 0.679 grams of Floccin™ HP (powdered) in a 100 ml sample and required moderate mixing. The dosage equates to a treatment of 56 lbs/1,000 gallons. The water still had a yellow tinge probably dissolved organics.

Recommended Treatment:
- Flocculation Skid
- Post-ozonation if color removal needed
Follow the links at the left for more industrial wastewater treatment manufacturing case studies.