Food Processing Wastewater Treatment Case Studies

Animal & Grease Rendering Facility Treatability Jar Test

The facility renders animals and restaurant grease as a means to recover protein.  The facility generates wastewater at 125,000 gal/day with the following analytical data as shown below.

  Untreated Treated % Reduction
Ammonia (NH3-N) 290 56 80.6%
Biochemical Oxygen Demand (BOD) 13,000 1600 87.7%
Chemical Oxygen Demand (COD) 22,000 4400 80%
Nitrate (NO3) ND ND N/A
Nitrogen – Total Kjedahl (TKN) 750 420 44%
Total Solids (TS) 7,700 2000 74%
Total Suspended Solids (TSS) 4000 40 99%
Total Volatile Solids (TVS) 7,200 770 89.3%

*units in mg/L = ppm

The jar test used Floccin 1103 at a dosage of 1.5 grams/liter which equates to 12.5 lbs/1,000 gallons.  Actual dosages will be adjusted depending on the final pond effluent water quality and RWQCB permitted levels.  The photos of Untreated and Treated are shown below:

Untreated Treated Animal Rendering WasteWater Samples Before and After Floccin™ Addition, Outstanding Results

 

 

Follow the links at the left for more industrial wastewater treatment food processing case studies.

Download This Case Study Here...

Download more manufacturing industry case studies here...

Get Started Your Optimization...Get Started